2.0 SCHEDULE OF DILAPIDATIONS |
|
External
Areas |
|
|
|
|
|
|
2.1 |
Rear elevation |
|
|
|
|
|
|
2.1.1 |
Rear brickwork elevations |
3.5 |
Brickwork is lightly soiled and stained at low level with some minor repointing required. |
Allow to clean down brickwork and repoint/repair brick elevations. |
440 |
|
85 |
2.1.2 |
Loading area and hardstanding |
3.5 |
Concrete surface loading area is soiled |
Thoroughly clean hardstanding area and remove all vegetation. |
140 |
|
120 |
2.1.3 |
Warehouse doors |
3.5.2 |
Doors are soiled. |
Clean down internal and external face of doors and thoroughly prepare. |
860 |
|
75 |
2.1.4 |
Bollards to parking area. |
3.5.2 |
Decorations to bollards are in poor condition. |
Allow to redecorate bollards. |
220 |
|
85 |
2.1.5 |
Warehouse up and over door |
3.5 |
2 no. panel damaged to door system. |
Allow to replace 1 no. panel to match existing door. |
1,360 |
|
440 |
2.2 |
Front elevation |
|
|
|
|
|
|
2.2.1 |
Low level brickwork |
3.5 |
Brickwork is lightly soiled and stained at low level. |
Clean down brickwork. |
320 |
|
32 |
2.2.2 |
Alarm box |
3.6 |
Tenant installed alarm box. |
Strip out alarm box and make good fixing holes with suitable rubber grommets. |
140 |
|
20 |
2.2.3 |
Window frames to front elevation |
3.5 |
Windows frames generally discoloured and decorations and framing. |
Allow to completely redecorate windows internally and externally and thoroughly clean windows and frames and glass on completion. |
4,400 |
Specialist paintwork |
525 |
2.2.4 |
Signage |
3.5 |
Tenant installed signage. |
Remove all tenant's signage and make good fixing holes with suitable rubber grommets. |
240 |
|
65 |
2.2.5 |
Front entrance doors |
3.5 |
Heavy staining and deterioration of decoration to doors. |
Thoroughly clean down frame and glazing and redecorate on completion. |
320 |
Specialist Paintwork |
320 |
2.2.6 |
Metal framed canopies to front elevation |
3.5 |
Canopies generally stained and soiled and decorations in poor condition. |
Allow to clean down canopies and redecorate framework on completion. |
720 |
|
220 |
|
INTERNAL
AREAS |
|
|
|
|
|
|
3.0 |
Warehouse |
|
|
|
|
|
|
3.0.1 |
Metal roof trusses and columns |
3.5 |
Metal roof trusses and columns require redecoration. |
Thoroughly prepare and redecorate metal roof trusses throughout warehouse area. |
3,920 |
Prerpare, prime undercoat and gloss incl Lift Hire |
1,050 |
3.0.2 |
Lights |
3.5 |
Fluorescent light fittings throughout warehouse are generally heavily soiled. |
Clean down all fluorescent lighting and ensure all fluorescent tubes are left working. 9 no. fittings not operational. |
600 |
Remove all fauly & supply and fit new fittings - to balance lighting levels over the whole floor area |
545 |
3.0.3 |
Tenant's installations |
3.6 |
Tenant installed equipment, cages and shelves to be removed from warehouse area. |
Strip out tenant installation and make good all damaged surfaces. |
12,400 |
Strip & make good all damaged services |
3,500 |
3.0.4 |
Perimeter wall |
3.5 |
Decorations to perimeter walls are generally soiled and tired. |
Allow to redecorate all perimeter walls, allow for all making good and preparation. |
5,820 |
|
3,265 |
3.0.5 |
Tenant installation |
3.6 |
Tenant installed electric conduit and power supplies installed to warehouse perimeter walls. |
Strip out all tenant installations and make good fixing holes. |
2,800 |
|
420 |
3.0.6 |
Floor slab |
3.5 |
Warehouse floor slab is heavily soiled and scuffed. |
Thoroughly clean and redecorate floor slab. Allow to renew all mastic movement joints. |
16,960 |
Clean only & make good movement joints - extent to be agreed with Surveyor based on original defects |
3,000 |
3.0.7 |
Electrical installations |
3.5 |
Tenant alterations to the original mains electrical installation. |
Upon removal of tenant installed fittings and wiring, carry out full periodic inspection and testing in accordance with BS: 7671 2001. Undertake all necessary works to ensure satisfactory compliance. Correctly label all wires and distribution board, fit engraved Traffolyte labels to all devices clearly identifying their function. |
6,000 |
Remove dead circuits Test and repair as Schedule of wants. Provide Cerificate on completion |
2,000 |
3.0.8 |
Doors from warehouse |
3.5 |
4 no. fire exit doors in poor decorative order. |
Thoroughly clean down doors and redecorate on completion. Ensure doors are in working order including replacing/overhauling all door furniture. |
320 |
Furniture & ease and adjust as necessary Redecoration |
460 |
3.0.9 |
Fire alarm installation |
3.6 |
Tenant alterations to fire alarm and lighting. |
Ensure system is left in full working order. Allow to clean down break glass call points, alarm sounders and detectors which are retained. |
800 |
Test & repair as necessary. Provide Certificate on completion |
200 |
3.0.10 |
Warehouse office |
3.5 |
Warehouse office decorations worn and tired. |
Allow to redecorate walls, floors and ceilings to offices. Allow for all necessary making good and removal of carpets etc… |
3,000 |
Remove carpet etc Clean, prepare and paint all surfaces |
420 |
3.1 |
Ground floor WCs within warehouse area |
|
|
|
|
|
|
3.1.1 |
Plaster ceiling |
3.5 |
Ceiling decorations generally soiled. |
Allow to completely clean and redecorate ceilings throughout WC areas. |
220 |
|
325 |
3.1.2 |
Wall decorations |
3.5 |
Wall decorations generally heavily soiled. |
Allow to completely redecorate walls to WC area. |
636 |
|
636 |
3.1.3 |
Doors, skirtings and architraves |
3.5 |
Decorations to skirtings, doors and architraves are generally soiled. |
Thoroughly prepare and redecorate timber skirtings, architraves and doors. Allow to overhaul/replace door furniture. |
1,280 |
|
385 |
3.1.4 |
Decorations to pipework |
|
Decorations to pipework etc are soiled. |
Thoroughly prepare and redecorate radiators and pipework throughout. |
180 |
|
120 |
3.1.5 |
Sanitary fixtures and fittings |
3.5 |
Heavy limescale build up and heavy soiling to sanitary fixtures and fittings generally. |
Allow to industrially clean all sanitary fixtures and fittings throughout. Should fittings not be able to be cleaned to an acceptable standard, then replacement will be required. |
2,400 |
Clean only |
220 |
3.1.6 |
Lighting to WCs |
3.5 |
2 no. missing diffusers and 2 no. defective lights. |
Allow to replace missing diffusers and repair defective lighting. |
80 |
|
80 |
3.1.7 |
Flooring |
3.5 |
Vinyl flooring generally worn and tired within WC areas. |
Allow to replace vinyl flooring to WC areas, allow to include lobbies etc.. |
680 |
2 No. Male Toilets |
840 |
3.1.8 |
Fracturing to walls and floors |
3.5 |
Investigate fracturing to walls and floors. |
Allow to carry out investigation to floors and walls. Allow for all necessary repairs prior to redecoration. |
3,500 |
Original condition & Quality of concrete flooring to dicatate extent of repairs. Provisional Sum |
2,500 |
3.2 |
Kitchenette |
|
|
|
|
|
|
3.2.1 |
Plaster ceiling |
3.5 |
Ceiling decorations generally soiled. |
Allow to completely clean and redecorate ceiling to kitchen areas. |
84 |
Redecoration to 3.2.1 to 3.2.4 |
380 |
3.2.2 |
Wall decorations |
3.5 |
Wall decorations generally heavily soiled. |
Allow to completely redecorate walls to kitchen areas. |
210 |
Above |
|
3.2.3 |
Doors, skirting and architraves |
3.5 |
Decorations to skirtings, doors and architraves are generally soiled. |
Thoroughly prepare and redecorate timber skirtings, architraves and doors. Allow to overhaul/replace door |
80 |
Above. Service replace Furniture |
140 |
3.2.4 |
Decorations to pipework |
3.5 |
Decorations to pipework etc are soiled. |
Thoroughly prepare and redecorate radiators and pipework throughout. |
46 |
Above |
|
3.2.5 |
Lighting to kitchen |
3.5 |
Lighting requires overhauling and diffusers cleaned. |
Allow to overhaul lighting. |
110 |
|
80 |
3.2.6 |
Flooring |
3.5 |
Vinyl flooring generally worn and tired within kitchen area. |
Allow to replace vinyl flooring to kitchen area. |
220 |
|
360 |
3.2.7 |
Kitchen sink and units |
3.6 |
Sink generally soiled and unit doors and ironmongery tiered. |
Clean sink unit and replace doors and ironmongery. |
410 |
Clean and service the units |
60 |
3.3 |
Lobbies to ground floor entrance and Ground Floor office space |
|
|
|
|
|
|
3.3.1 |
Plastered ceilings (including staircase) |
3.5 |
Plastered ceilings generally soiled. |
Allow to repair and carry out complete redecoration to all ceilings and soffits. |
960 |
|
825 |
3.3.2 |
Plastered wall coverings |
3.5 |
Decorations to walls are generally soiled. |
Allow to carry out complete redecoration to all finishes. Allow to repair all blown plaster prior to redecoration. |
2,120 |
|
960 |
3.3.3 |
Timberwork |
3.5 |
Timber decorations are generally soiled including all doors leading off lobbies to WC offices and warehouse. |
Thoroughly prepare and redecorate timber skirtings, doors, architraves and door fascias. 10 no. doors in total. |
1,520 |
|
850 |
3.3.4 |
Doors |
3.5 |
Fire doors leading from main lobby. |
Allow to overhaul and repair doors as necessary including ironmongery. 5 no. doors. |
450 |
Repair/renew
furniture |
250 |
3.3.5 |
Staircase |
3.5 |
Decoration to timberwork and metalwork generally soiled. |
Thoroughly prepare and redecorate. |
284 |
Two staircases |
560 |
3.3.6 |
Floor covering |
3.5 |
Carpet floor coverings to office, staircases and lobbies are generally soiled and worn. |
Take up carpet floor covering to office, lobbies, staircases and replace. |
720 |
Unit 19 only. Carry out deep clean for Surveyor's inspection |
720 |
3.3.7 |
Radiators |
3.5 |
Radiators and paintwork are generally soiled. |
Thoroughly prepare and redecorate radiators and pipework. |
220 |
|
120 |
3.3.8 |
Intruder alarm |
3.6 |
Tenant installed intruder alarm |
Strip out tenant installed tenant intruder alarm including all alarms bells, key pads, cables and sensors and make good all fixing holes on completion. |
360 |
|
140 |
3.3.9 |
Lighting |
3.5 |
Lighting requires overhauling and diffusers cleaned. |
Allow to overhaul lighting. |
110 |
|
110 |
3.3.10 |
Cleaner's cupboard. |
3.5 |
Decorations generally soiled. |
Allow to prepare and redecorate cleaner's cupboard. |
240 |
|
80 |
3.3.11 |
Stair nosing |
3.5 |
Damaged stair nosing |
Replace 26no. Stair nosing to match existing. |
258 |
|
110 |
3.3.12 |
Tenants alterations |
3.6 |
Tenant installed security lobby |
Remove tenant installed security lobby, including doors, partitions, door closers and entrance system. Allow to make good on completion. |
250 |
Removal only. Redecoration above |
50 |
3.4 |
Ground floor male and female WCs |
|
|
|
|
|
|
3.4.1 |
Ceiling |
3.5 |
Plaster ceiling lightly soiled. |
Repair and redecorate ceiling. |
320 |
|
85 |
3.4.2 |
Plastered walls |
3.5 |
Plastered walls soiled and minor damage. |
Thoroughly prepare and redecorate. Allow to repair fracture to walls prior to redecoration. |
680 |
|
220 |
3.4.3 |
Decorations |
3.5 |
Decorations to timber skirting radiators and pipework are soiled. |
Thoroughly prepare and redecorate timber skirtings, radiators and pipework. |
400 |
|
100 |
3.4.4 |
Sanitaryware |
3.5 |
Sanitaryware is generally soiled. |
Thoroughly industrially clean all sanitaryware. |
160 |
Included above |
|
3.4.5 |
Vinyl floor covering |
3.5 |
Vinyl floor covering is soiled. |
Allow to industrially clean vinyl floor tiles throughout. Allow to repair damaged tiles to match existing. |
360 |
Clean & replace all damaged tiles to match as near as possible |
450 |
3.5 |
First floor offices |
|
|
|
|
|
|
3.5.1 |
Ceilings |
3.5 |
Suspended ceiling generally soiled and a number of tiles punctured and damaged. |
Allow to thoroughly clean down grid and replace all missing and damaged panels. |
800 |
Metal Cover plates to existing holes with electrical plates Clean etc |
500 |
3.5.2 |
Lighting |
3.5 |
Fluorescent lighting throughout office areas. |
3 no. missing tubes from fluorescent lights. Allow to replace 3 no. missing tubes. |
36 |
Replace 3 No. fittings. Replace damaged tiles |
180 |
3.5.3 |
Walls |
3.5 |
Plaster decorated walls generally soiled and minor damage in isolated locations. |
Thoroughly prepare and redecorate walls. Allow to repair all fractures to walls prior to redecoration. |
1,080 |
Damage adjacent to windows - existing design defects prior to occupation - to be agreed with Surveyor |
500 |
3.5.4 |
Steel panel radiators |
3.5 |
Radiators are lightly soiled. |
Make good and thoroughly prepare and redecorate panels and pipework on completion. |
360 |
|
150 |
3.5.5 |
Tenant installed partitioning |
3.6 |
Tenant installed demountable partitioning forming cellular office space. |
Strip out partitioning and make good fixing holes. |
900 |
Includes Cart away from site with other debris including patching carpet |
250 |
3.5.6 |
Carpet floor covering |
3.5 |
Carpet floor covering is worn in areas. |
Strip up floor coverings and replace with quality to match existing. |
4,600 |
Deep clean all areas for Surveyor's inspection |
1,000 |
3.5.7 |
Timber skirting |
3.5 |
Timber skirting decorations are generally soiled and where cables have been attached fixing holes are present. |
Make good fixing holes and thoroughly prepare and redecorate. |
420 |
|
120 |
3.5.8 |
Telecommunic ations and data cabling |
3.6 |
Tenant installed telecommunications and computer cabling. |
Strip all tenant installed data, telecomms and other wiring from all floors, walls, risers, conduits and ceiling voids. Remove all voice and data outlets and cabling throughout. Take down and remove all telephone exchanges and distribution cabling to offices and risers. Ensure landlord's power and lighting cabling is left intact. Replace all missing trunking covers following this. Remove all tenant installed surface fixed conduits, junction boxes, socket points, outlets and other associated fixings. Make good all surfaces disturbed. |
2,400 |
|
750 |
3.5.9 |
Small power |
3.5 |
Light switches installed are generally soiled. |
Thoroughly clean on completion. |
40 |
Replace if necessary |
120 |
3.5.10 |
Doors and architraves |
3.5 |
Doors and architraves are lightly soiled. |
Thoroughly prepare and redecorate doors and architraves. |
480 |
|
170 |
3.5.11 |
Door keys |
3.6 |
Door keys are not present in doors. |
Supply landlord with door keys. |
|
Tenant has all keys |
|
3.5.12 |
Light fittings |
3.5 |
3 no. missing fluorescent tubes. |
Replace missing fluorescent tubes. |
195 |
Repeated item |
|
3.5.13 |
Window Boards |
3.5 |
Decorations in poor condition. |
Allow to prepare and redecorate timber window boards. |
416 |
|
240 |
3.5.14 |
Doors |
3.5 |
Damaged doors and ironmongery. |
Repair doors and replace ironmongery as necessary. |
800 |
|
320 |
3.6 |
General items |
|
|
|
|
|
|
3.6.1 |
Fire alarm |
3.23 |
No evidence of maintenance of fire alarm system. |
Inspect and test fire alarm system in accordance with BS: 5839. Provide test certificate, undertake all necessary works to ensure satisfactory compliance. |
2,000 |
|
220 |
3.6.2 |
Asbestos containing material |
3.23 |
Asbestos containing material. There is no asbestos register on site, in breach of CAWR 2002. |
Obtain an up to date asbestos register with results of all sample testing and asbestos surveys. Carry out all appropriate remedial works in accordance with regulations and update asbestos management policy. |
|
|
|
3.6.3 |
Windows |
3.5 |
Windows are soiled. |
Clean all windows |
|
|
|
3.6.4 |
Access |
3.5 |
Scaffold/powered access, fall restraint required to undertake works. Compartmentation |
Provide all necessary access to suitably undertake works.
Block up doors between Units |
|
|
600 |
|
|
|
|
Total |
113,105 |
|
36,308 |